Scheme 1: only the sensor is required to transmit the shaft sinking displacement data to the DCS or PLC data terminal, and there is no need to provide the output contact of the shaft sinking displacement signal alarm relay and the field data display. It is recommended to choose the two-wire integrated displacement transmitter solution produced by Shanghai Ruishi Company.


1. The subsidence displacement of the shaft ranges from-1 mm to+1 mm or 0.5 mm to+2.5 mm.

Choose Shanghai Ruishi eddy current 8mm probe+extension cable+RS991 Eddy Current Two-wire Displacement Transmitter;

 2. The settlement displacement of shaft ranges from-2mm to+2mm or 0.5mm to+4.0mm or 0.5mm to+4.5mm.

 Shanghai Ruishi eddy current 11mm probe+extension cable+RS991 Eddy Current Two-wire Displacement Transmitter is selected; 

3.png


Scheme 2. The sensor is required to transmit the data of shaft sinking displacement to DCS or PLC data terminal, and the output contact of alarm relay of shaft sinking displacement data is required to provide field data display. It is recommended to choose the 4 channel and 2 channel protection instrument devices produced by Shanghai Ruishi Company.

4.png


Previous:none

Next:none

Shanghai Ruishi Instrument Electronics Co., Ltd.
Scan QR code
follow Ruishi
Contact us

Headquarters address:No.118, Building 54, Lane 255, Sizhuan South Road, Songjiang District, Shanghai (Famous Enterprise Mansion)

Sales hotline:021-67871955/54425984

Fax:021-54865118

Zip code:201612

Person in charge:13601921246

Mailbox:13601921246@163.com

Website Support | Nuoqi Science& Technology Co., Ltd. All rights reserved 沪ICP备18029944号-1
Baidu
sogou